|   | Rx61-22 Instructions (v6.0.2) | 
|   |   |   |   | 
1. DEFAULT SETUP
| Item | Setting | Details | 
| Purpose: | Rx61-2 | Train with Tx22 transmitter | 
| Red wire positive (+) Black wire negative (-) | Battery | 3-16v Observe polarities | 
| Integrated BEC | 4v | Suitable to power 1 small servo | 
| H1 output Brown wires | Motor Speed knob (Ch1) | Integrated forward/reverse ESC for brushed motors Center off | 
| P1 output | Servo Bind button (Ch5) | Slow-motion servo for coupling Integrated 4v power supply for servo (BEC) Press bind button to open coupling Release bind button to close coupling | 
| P2 output | Front Light Direction switch (Ch3) | Led needs current limiting resistor Direction switch 'up' for on (center off) | 
| P3 output | Rear Light Direction switch (Ch3) | Led needs current limiting resistor Direction switch 'down' for on (center off) | 
| P5 output | On/Off Bind button (Ch5) | Item being switched needs current limiting resistor ON while button pressed, OFF when released | 
| P4 output | Light (Ch4) | Not used with Tx22 | 
| P6 output | Light (Ch6) | Not used with Tx22 | 
| P7 output | Light (Ch7) | Not used with Tx22 | 
| Selecta | Enabled | Up to 12 locos can be associated with Selecta switch on Tx22 The selector switch position is memorised during binding. Rx 'holds' motor setting when deselected (suitable for continuous loop) Led 2-flash if loco is not currently selected | 
| Arming: | Enabled | Motor control knob to center position (off) | 
| LVC | Enabled | LVC=Low Voltage Cutoff Led 5-flash if triggered Stop and charge battery | 
| Inactivity Sleep | Enabled | After 1 hour Switch off and on to restart | 
2. EXAMPLE CONNECTIONS:
|   |   |   | 
'P' outputs are 3v when on and 0v when off. Led's need resistors to limit current to 20mA but high brightness led's allow a lower current (eg: 2-5mA). Google will reveal how to select resistor values but 220-470ohms will be safe starting values.
The 4v BEC output is suitable to power a small servo when the Rx is powered with a higher voltage. When the Rx is powered with 1S lipo, it would be more normal to power a servo direct from the lipo
3. BINDING
Bind once (not necessary if Rx was supplied pre-bound):
1. Switch Rx on and wait ~20s until led flickers fast.
2. Choose the Selecta switch position for this loco.
3. Switch Tx on in bind mode.
4. Rx led should flash slowly; wait for it to go solid.
Change distance between Tx/Rx if binding does not work.
4. LED:
Led On  = perfect reception (real-time indicator).
1 flash = Scanning (~2sec between flashes; no signal or not bound if never stops).
2 flash = Loco not selected.
5 flash = LVC/Brownout (voltage went too low; check battery/motor load).
5. FAILSAFE:
The motor output is not active on startup and while scanning for a signal.
The motor output 'holds' last known settings on short signal losses (<1sec) and then slows to a stop over 3 seconds.
6. OTHER:
This receiver has other features that are not described.
These are changed using a technique called 'programming':
| Version | v6.0.2 v6.0.1 |